Subjective speech quality measurement with and without parallel task: Laboratory test results comparison
Gorde:
| Argitaratua izan da: | PLoS One vol. 13, no. 7 (Jul 2018), p. e0199787 |
|---|---|
| Egile nagusia: | |
| Beste egile batzuk: | |
| Argitaratua: |
Public Library of Science
|
| Gaiak: | |
| Sarrera elektronikoa: | Citation/Abstract Full Text Full Text - PDF |
| Etiketak: |
Etiketarik gabe, Izan zaitez lehena erregistro honi etiketa jartzen!
|
| Laburpena: | This paper focuses on a novel methodology of subjective speech quality measurement and repeatability of its results between laboratory conditions and simulated environmental conditions. A single set of speech samples was distorted by various background noises and low bit-rate coding techniques. This study aimed to compare results of subjective speech quality tests with and without a parallel task deploying the ITU-T P.835 methodology. Afterward, tests results performed with and without a parallel task were compared using Pearson correlation, CI95, and numbers of opposite pair-wise comparisons. The tests show differences in results in the case of a parallel task. |
|---|---|
| ISSN: | 1932-6203 |