IMPACT OF POWER ELECTRONICS DEVICES ON LEAKAGE CURRENT IN MINE ELECTRICAL SYSTEMS: A CASE STUDY IN VIETNAM

-д хадгалсан:
Номзүйн дэлгэрэнгүй
-д хэвлэсэн:Natsional'nyi Hirnychyi Universytet. Naukovyi Visnyk no. 1 (2025), p. 55
Үндсэн зохиолч: Y, Do Nhu
Бусад зохиолчид: Giang, Nguyen Truong, Cuong, Ngo Xuan, Khanh, Nguyen Thac, Tuan, Le Anh
Хэвлэсэн:
State Higher Educational Institution "National Mining University"
Нөхцлүүд:
Онлайн хандалт:Citation/Abstract
Full Text
Full Text - PDF
Шошгууд: Шошго нэмэх
Шошго байхгүй, Энэхүү баримтыг шошголох эхний хүн болох!

MARC

LEADER 00000nab a2200000uu 4500
001 3176002645
003 UK-CbPIL
022 |a 2071-2227 
022 |a 2223-2362 
024 7 |a 10.33271/nvngu/2025-1/055  |2 doi 
035 |a 3176002645 
045 2 |b d20250101  |b d20250228 
084 |a 185328  |2 nlm 
100 1 |a Y, Do Nhu  |u Hanoi University of Mining and Geology, Hanoi, the Socialist Republic of Vietnam 
245 1 |a IMPACT OF POWER ELECTRONICS DEVICES ON LEAKAGE CURRENT IN MINE ELECTRICAL SYSTEMS: A CASE STUDY IN VIETNAM 
260 |b State Higher Educational Institution "National Mining University"  |c 2025 
513 |a Case Study Journal Article 
520 3 |a Purpose. To determine the impact of power electronic devices on leakage current in underground mine AC power network. The research results allow choosing appropriate leakage protection method to improve electrical safety in underground mining. Methodology. This study uses analytical methods and modeling methods on Matlab/Simulink software to determine, analyze, and evaluate the working current and leakage current in the mine power network containing power electronic devices. F ndings. A mine power network model containing inverter and electric motor was built by analytical method and simulated using Matlab/Simulink with model parameters U= 1,140 V, C = 0.19 uF/phase, R = 168 kQ/phase. The research results show that, with a leakage resistance of 1 kQ, the leakage current value in the AC network with a frequency other than 50 Hz after the inverter (467 mA) is 1.52 times higher than the leakage current value in the AC network with a frequency of 50 Hz before the inverter (307 mA), and at the same time, many high-order harmonie components appear in the 50 Hz AC network with THD = 1.77. In addition, the research results also show that the leakage current in the AC network before and after the inverter depends less on the insulation resistance of the DC network but depends mainly on the insulation of the AC network, the leakage resistance and the operating frequency of the AC network. Originality. Leakage current in AC power network containing power electronic devices in mining in Vietnam is studied. The research results show that when using a mine power network with an inverter, the leakage current on the AC side after the inverter has a larger value than the leakage current of the AC side before the inverter. Practical value. The research results allow choosing the appropriate leakage protection method to improve electrical safety in underground mining. 
651 4 |a Vietnam 
653 |a Analytical methods 
653 |a Underground mining 
653 |a Insulation 
653 |a Control algorithms 
653 |a Cables 
653 |a Underground mines 
653 |a Mining 
653 |a Electronic devices 
653 |a Matlab 
653 |a Leakage 
653 |a Inverters 
653 |a Electric motors 
653 |a Measurement techniques 
653 |a Electrical equipment 
653 |a Electronic equipment 
653 |a Alternating current 
653 |a Leakage current 
653 |a Mining accidents & safety 
653 |a Electrical safety 
653 |a Economic 
700 1 |a Giang, Nguyen Truong  |u Hanoi University of Mining and Geology, Hanoi, the Socialist Republic of Vietnam 
700 1 |a Cuong, Ngo Xuan  |u School of Engineering and Technology, Hue University, Thua Thien Hue, the Socialist Republic of Vietnam 
700 1 |a Khanh, Nguyen Thac  |u Hanoi University of Mining and Geology, Hanoi, the Socialist Republic of Vietnam 
700 1 |a Tuan, Le Anh  |u Hanoi University of Industry, Hanoi, the Socialist Republic of Vietnam 
773 0 |t Natsional'nyi Hirnychyi Universytet. Naukovyi Visnyk  |g no. 1 (2025), p. 55 
786 0 |d ProQuest  |t Materials Science Database 
856 4 1 |3 Citation/Abstract  |u https://www.proquest.com/docview/3176002645/abstract/embedded/7BTGNMKEMPT1V9Z2?source=fedsrch 
856 4 0 |3 Full Text  |u https://www.proquest.com/docview/3176002645/fulltext/embedded/7BTGNMKEMPT1V9Z2?source=fedsrch 
856 4 0 |3 Full Text - PDF  |u https://www.proquest.com/docview/3176002645/fulltextPDF/embedded/7BTGNMKEMPT1V9Z2?source=fedsrch