Effect of Beam Bracing on the Seismic Performance of Laterally Skewed Reduced Beam Section Moment Connections With Composite Concrete Slabs

Guardado en:
Bibliografiske detaljer
Udgivet i:ProQuest Dissertations and Theses (2025)
Hovedforfatter: Ghimire, Pratik
Udgivet:
ProQuest Dissertations & Theses
Fag:
Online adgang:Citation/Abstract
Full Text - PDF
Tags: Tilføj Tag
Ingen Tags, Vær først til at tagge denne postø!

MARC

LEADER 00000nab a2200000uu 4500
001 3219168427
003 UK-CbPIL
020 |a 9798280773776 
035 |a 3219168427 
045 2 |b d20250101  |b d20251231 
084 |a 66569  |2 nlm 
100 1 |a Ghimire, Pratik 
245 1 |a Effect of Beam Bracing on the Seismic Performance of Laterally Skewed Reduced Beam Section Moment Connections With Composite Concrete Slabs 
260 |b ProQuest Dissertations & Theses  |c 2025 
513 |a Dissertation/Thesis 
520 3 |a Existing experimental reduced beam section (RBS) moment frame investigations, particularly those used for prequalification in AISC-358, consider orthogonally oriented beam-to-column connections. While the design commentary provided in AISC-358 references recent skewed SMF numerical studies and potential performance effects when a lateral beam skew is introduced, limited experimental studies have been performed to verify the numerical findings. This study presents an experimental investigation into the cyclic behavior of RBS special moment frames that have lateral skew at the beam-to-column connection and composite concrete slabs. In this study, a skewed composite double-sided RBS connection is tested, having beam bracing outside the RBS connection to contrast observed behavior with recent testing neglecting RBS bracing, as is allowed when a slab is present. The test specimen in this study considers a W24x131 column and two W24x76 beams connected at a 15-degree lateral skew angle. Experimental results show that the connection retained 80% of its plastic moment capacity during 4% drift, meeting AISC-358 prequalification requirements. A beam top-flange fracture was observed at 6% drift due to ultra-low cycle fatigue resulting from the repeated local buckling of the beam flange. Moderate column twisting, and minimal column flange yielding at the acute skew angle side of the connection were observed. Inelastic deformation was successfully localized to the RBS region and there were no signs of the connection weld fractures. Comparing results with previous testing neglecting beam bracing, lateral beam bracing within d/2 from the RBS is recommended for connections having beam skews greater than 10 degrees, even if a composite concrete slab is present. 
653 |a Civil engineering 
653 |a Environmental engineering 
773 0 |t ProQuest Dissertations and Theses  |g (2025) 