New parametric computational test case for automated design and analysis of an axial blood pump

Guardado en:
Detalles Bibliográficos
Publicado en:Archive of Mechanical Engineering vol. 72, no. 3 (2025), p. 405-434
Autor principal: Linkeová, Ivana
Otros Autores: Bodnár, Tomáš, Lancmanová, Anna, Pirkl, Luboš
Publicado:
Polish Academy of Sciences
Materias:
Acceso en línea:Citation/Abstract
Full Text - PDF
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!

MARC

LEADER 00000nab a2200000uu 4500
001 3263444413
003 UK-CbPIL
022 |a 0004-0738 
022 |a 2300-1895 
024 7 |a 10.24425/ame.2025.155869  |2 doi 
035 |a 3263444413 
045 2 |b d20250701  |b d20250930 
084 |a 188536  |2 nlm 
100 1 |a Linkeová, Ivana 
245 1 |a New parametric computational test case for automated design and analysis of an axial blood pump 
260 |b Polish Academy of Sciences  |c 2025 
513 |a Journal Article 
520 3 |a The paper presents a new fully parametric geometrical model of a ventricular assist device (VAD) together with an example of a comprehensive automated workflow integrating multidisciplinary tools for geometrical design, fluid dynamic assessment, and automated shape optimisation. Advanced geometrical constructions are applied to develop a new fully parametric CAD (Computer Aided Design) model that generates a stable, watertight geometry of an axial blood pump in both non-uniform B-spline representation and node-to-node triangular mesh. The presented example of a fully integrated simulation workflow that combines open-source software tools within a user-friendly environment, demonstrates its efficiency while benefiting from the fully parametric, easily adjustable VAD model. The proposed geometrical modelling and numerical simulation approach offers a seamless, ready-to-use test case for computer aided design, analysis and optimisation of VADs. The shown results demonstrate the essential advantages of the parametric modelling approach, showcasing its potential application in performance improvements of an axial blood pump through shape optimisation. Overall, the paper highlights the viability of automated, multidisciplinary design workflows in biomedical engineering. 
653 |a Design analysis 
653 |a Blood pumps 
653 |a B spline functions 
653 |a Modelling 
653 |a Computer aided design--CAD 
653 |a Workflow 
653 |a Ventricular assist devices 
653 |a Biomedical engineering 
653 |a Computer aided testing 
653 |a Automation 
653 |a Design optimization 
653 |a Open source software 
653 |a Axial flow pumps 
700 1 |a Bodnár, Tomáš 
700 1 |a Lancmanová, Anna 
700 1 |a Pirkl, Luboš 
773 0 |t Archive of Mechanical Engineering  |g vol. 72, no. 3 (2025), p. 405-434 
786 0 |d ProQuest  |t Engineering Database 
856 4 1 |3 Citation/Abstract  |u https://www.proquest.com/docview/3263444413/abstract/embedded/6A8EOT78XXH2IG52?source=fedsrch 
856 4 0 |3 Full Text - PDF  |u https://www.proquest.com/docview/3263444413/fulltextPDF/embedded/6A8EOT78XXH2IG52?source=fedsrch