Development of a Fuzzy Impedance Distance Protection Scheme to Enhance Fault Detection and Mitigate Power Swings in Electrical Power Grid

Збережено в:
Бібліографічні деталі
Опубліковано в::Journal Europeen des Systemes Automatises vol. 58, no. 10 (Oct 2025), p. 2101-2112
Автор: Mohammed Riyadh Y. Al-Fakhar
Інші автори: Ahmed Nasser B. Alsammak
Опубліковано:
International Information and Engineering Technology Association (IIETA)
Предмети:
Онлайн доступ:Citation/Abstract
Full Text - PDF
Теги: Додати тег
Немає тегів, Будьте першим, хто поставить тег для цього запису!

MARC

LEADER 00000nab a2200000uu 4500
001 3283331409
003 UK-CbPIL
022 |a 1269-6935 
022 |a 2116-7087 
024 7 |a 10.18280/jesa.581010  |2 doi 
035 |a 3283331409 
045 2 |b d20251001  |b d20251031 
100 1 |a Mohammed Riyadh Y. Al-Fakhar 
245 1 |a Development of a Fuzzy Impedance Distance Protection Scheme to Enhance Fault Detection and Mitigate Power Swings in Electrical Power Grid 
260 |b International Information and Engineering Technology Association (IIETA)  |c Oct 2025 
513 |a Journal Article 
520 3 |a Protection mechanisms are essential to prevent catastrophic failures and ensure power network stability. However, accurately identifying and characterising power flows remains challenging, especially when fault resistance and location change. Incorrect fault identification may cause overall system instability and loss of synchronisation. This work presents a novel protection method to improve fault detection and reduce power swings by integrating a fuzzy inference system (FIS) with distance relays and a specialized proposed stability boundary curve. This method effectively differentiates between stable, critical, and unstable power swings, using fuzzy logic to enhance the sensitivity and accuracy of fault and power swing diagnosis. The proposed system allows intelligent load-shedding strategies to restore system stability when needed and can adapt to various fault resistances and locations. The protection system combines the distance relay, the stability boundary curve, and a Sugeno-type FIS. The technique was validated through MATLAB/Simulink simulations on a power system consisting of three buses and two generators. Simulations on a 700 km transmission line demonstrated the system’s efficiency in both fast fault detection (T2) and precise stability evaluation (T4-T2). Load-shedding strategies were applied, which contributed to system recovery, demonstrating the reliability and strength of the proposed system in avoiding major outages. 
653 |a Methods 
653 |a Wavelet transforms 
653 |a Systems stability 
653 |a Fourier transforms 
653 |a Fuzzy logic 
700 1 |a Ahmed Nasser B. Alsammak 
773 0 |t Journal Europeen des Systemes Automatises  |g vol. 58, no. 10 (Oct 2025), p. 2101-2112 
786 0 |d ProQuest  |t ABI/INFORM Global 
856 4 1 |3 Citation/Abstract  |u https://www.proquest.com/docview/3283331409/abstract/embedded/7BTGNMKEMPT1V9Z2?source=fedsrch 
856 4 0 |3 Full Text - PDF  |u https://www.proquest.com/docview/3283331409/fulltextPDF/embedded/7BTGNMKEMPT1V9Z2?source=fedsrch