Effect of a blind spot in a dielectrophoretic field on the separation of human breast cancer cells (MCF 7)

Պահպանված է:
Մատենագիտական մանրամասներ
Հրատարակված է:Journal of Mechanical Science and Technology vol. 23, no. 11 (Nov 2009), p. 3132
Հիմնական հեղինակ: Kim, Youngho
Այլ հեղինակներ: Lee, Jangwon, An, Jaemin, Lee, Sang Ho, Kim, Byungkyu
Հրապարակվել է:
Springer Nature B.V.
Խորագրեր:
Առցանց հասանելիություն:Citation/Abstract
Full Text
Full Text - PDF
Ցուցիչներ: Ավելացրեք ցուցիչ
Չկան պիտակներ, Եղեք առաջինը, ով նշում է այս գրառումը!

MARC

LEADER 00000nab a2200000uu 4500
001 881602878
003 UK-CbPIL
022 |a 1738-494X 
022 |a 1976-3824 
022 |a 1226-4865 
024 7 |a 10.1007/s12206-009-0910-6  |2 doi 
035 |a 881602878 
045 2 |b d20091101  |b d20091130 
084 |a 137836  |2 nlm 
100 1 |a Kim, Youngho 
245 1 |a Effect of a blind spot in a dielectrophoretic field on the separation of human breast cancer cells (MCF 7) 
260 |b Springer Nature B.V.  |c Nov 2009 
513 |a Feature 
520 3 |a Previously, we proposed a 'dielectrophoretically activated cell sorting' (DACS) system, which can be applied to the separation of various cells without labeling them with magnetic or fluorescent materials. By using a specific frequency range, it was verified that the dielectric material properties of cells can be exploited in order to collect target cells from a cell mixture. However, because about 20% of the error in separation efficiencies was always detected, it became a subject to investigate. Therefore, we assumed that variance in cell size might be responsible for the errors. By measuring the diameter of human breast cancer cells (MCF 7) and classifying separation efficiencies according to diameter, it was verified that the errors in separation efficiency are affected by cell size. Moreover, the existence of a 'blind spot,' i.e., a space with weak force within the dielectrophoretic field generated by a pair of electrodes, was proven by commercial code CFD-ACE^sup +®^. With simulation and experimental results, we demonstrated that some efficiency errors occur because small sized cells (between 15 and 20 μm) pass through the 'blind spot'.[PUBLICATION ABSTRACT] 
653 |a Breast cancer 
700 1 |a Lee, Jangwon 
700 1 |a An, Jaemin 
700 1 |a Lee, Sang Ho 
700 1 |a Kim, Byungkyu 
773 0 |t Journal of Mechanical Science and Technology  |g vol. 23, no. 11 (Nov 2009), p. 3132 
786 0 |d ProQuest  |t Advanced Technologies & Aerospace Database 
856 4 1 |3 Citation/Abstract  |u https://www.proquest.com/docview/881602878/abstract/embedded/ZKJTFFSVAI7CB62C?source=fedsrch 
856 4 0 |3 Full Text  |u https://www.proquest.com/docview/881602878/fulltext/embedded/ZKJTFFSVAI7CB62C?source=fedsrch 
856 4 0 |3 Full Text - PDF  |u https://www.proquest.com/docview/881602878/fulltextPDF/embedded/ZKJTFFSVAI7CB62C?source=fedsrch