Quality control for single-cell analysis of high-plex tissue profiles using CyLinter

Shranjeno v:
Bibliografske podrobnosti
izdano v:Nature Methods vol. 21, no. 12 (Dec 2024), p. 2248
Izdano:
Nature Publishing Group
Teme:
Online dostop:Citation/Abstract
Full Text - PDF
Oznake: Označite
Brez oznak, prvi označite!

MARC

LEADER 00000nab a2200000uu 4500
001 3141257616
003 UK-CbPIL
022 |a 1548-7091 
022 |a 1548-7105 
024 7 |a 10.1038/s41592-024-02328-0  |2 doi 
035 |a 3141257616 
045 2 |b d20241201  |b d20241231 
084 |a 68926  |2 nlm 
245 1 |a Quality control for single-cell analysis of high-plex tissue profiles using CyLinter 
260 |b Nature Publishing Group  |c Dec 2024 
513 |a Journal Article 
520 3 |a Tumors are complex assemblies of cellular and acellular structures patterned on spatial scales from microns to centimeters. Study of these assemblies has advanced dramatically with the introduction of high-plex spatial profiling. Image-based profiling methods reveal the intensities and spatial distributions of 20–100 proteins at subcellular resolution in 103–107 cells per specimen. Despite extensive work on methods for extracting single-cell data from these images, all tissue images contain artifacts such as folds, debris, antibody aggregates, optical aberrations and image processing errors that arise from imperfections in specimen preparation, data acquisition, image assembly and feature extraction. Here we show that these artifacts dramatically impact single-cell data analysis, obscuring meaningful biological interpretation. We describe an interactive quality control software tool, CyLinter, that identifies and removes data associated with imaging artifacts. CyLinter greatly improves single-cell analysis, especially for archival specimens sectioned many years before data collection, such as those from clinical trials.Microscopy artifacts and tissue imperfections interfere with single-cell analysis. CyLinter software offers quality control for high-plex tissue profiling by removing artifactual cells, thereby facilitating accuracy of biological interpretation. 
653 |a Clinical trials 
653 |a Data acquisition 
653 |a Software 
653 |a Quality control 
653 |a Assemblies 
653 |a Image processing 
653 |a Spatial distribution 
653 |a Artifact identification 
653 |a Defects 
653 |a Data collection 
653 |a Specimen preparation 
653 |a Interactive control 
653 |a Data processing 
653 |a Data analysis 
653 |a Impact analysis 
653 |a Image acquisition 
653 |a Optical data processing 
653 |a Image quality 
653 |a Cellular structure 
653 |a Environmental 
773 0 |t Nature Methods  |g vol. 21, no. 12 (Dec 2024), p. 2248 
786 0 |d ProQuest  |t Science Database 
856 4 1 |3 Citation/Abstract  |u https://www.proquest.com/docview/3141257616/abstract/embedded/6A8EOT78XXH2IG52?source=fedsrch 
856 4 0 |3 Full Text - PDF  |u https://www.proquest.com/docview/3141257616/fulltextPDF/embedded/6A8EOT78XXH2IG52?source=fedsrch