Material Selection for the Development of Orthoses Using Multicriteria Methods (MCDMs) and Simulation

Guardado en:
Detalles Bibliográficos
Publicado en:Processes vol. 13, no. 6 (2025), p. 1796-1817
Autor principal: Salazar Loor Rodger Benjamin
Otros Autores: Martínez-Gómez, Javier, Sarmiento, Anchundia Josencka
Publicado:
MDPI AG
Materias:
Acceso en línea:Citation/Abstract
Full Text + Graphics
Full Text - PDF
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
Descripción
Resumen:Low-energy bone fractures refer to injuries that occur from minimal trauma or impact. These fractures are often a result of activities, such as falls from standing height or minor accidents, where the force exerted on the bone is insufficient to cause a break under normal conditions. To design an effective orthotic splint, it is critical to select the appropriate material that mimics the mechanical properties of traditional materials like plaster, which has long been used for immobilization purposes. In this case, Ansys CES Edupack 2025 software was utilized to evaluate and identify materials with mechanical characteristics similar to those of plaster. The software provided a list of six materials that met these criteria, but selecting the most suitable material involved more than just mechanical properties. Three different multicriteria decision-making methods were employed to ensure the best choice: TOPSIS, VIKOR, and COPRAS. These methods were applied to consider various factors, such as strength, flexibility, weight, cost, and ease of manufacturing. The results of the analyses revealed a strong consensus across all three methods. Each approach identified PLA (Polylactic Acid) as the most appropriate material for the orthotic design. Following the material selection process, simulations were conducted to assess the structural performance of the orthotic splint. The results determined that the minimum thickness required for the PLA orthosis was 4 mm, ensuring that it met all necessary criteria for acceptable stresses and deformations during the four primary movements exerted by the wrist. This thickness was sufficient to maintain the orthosis’s functionality without compromising comfort or effectiveness. Moreover, a significant improvement in the design was achieved through topological optimization, where the mass of the preliminary design was reduced by 9.58%, demonstrating an efficient use of material while maintaining structural integrity.
ISSN:2227-9717
DOI:10.3390/pr13061796
Fuente:Materials Science Database