Contractile force measurements of cardiac myocytes using a micro-manipulation system

Збережено в:
Бібліографічні деталі
Опубліковано в::Journal of Mechanical Science and Technology vol. 20, no. 5 (May 2006), p. 668
Автор: Park, Sukho
Інші автори: Ryu, Seokkyu, Ryu, Seokchang, Kim, Deokho, Kim, Byungkyu
Опубліковано:
Springer Nature B.V.
Предмети:
Онлайн доступ:Citation/Abstract
Full Text
Full Text - PDF
Теги: Додати тег
Немає тегів, Будьте першим, хто поставить тег для цього запису!
Опис
Короткий огляд:In order to develop a cell based robot, we present a micro-mechanical force measurement system for the biological muscle actuators, which utilize glucose as a power source. The proposed measurement system is composed of a micro-manipulator, a force transducer with a glass probe, a signal processor, an inverted microscope and video recording system. Using this measurement system, the contractile force and frequency of the cardiac myocytes were measured in real time and the magnitudes of the contractile force of each cardiac myocyte under different conditions were compared. From the quantitative experimental results, we could estimate that the force of cardiac myocytes is about 20-40 μN, and show that there are differences between the control cells and the micro-patterned cells.[PUBLICATION ABSTRACT]
ISSN:1738-494X
1976-3824
1226-4865
DOI:10.1007/BF02915984
Джерело:Advanced Technologies & Aerospace Database